SP-300 Pstat/Gstat

SP-300 Pstat/Gstat

Up to 2 Channels, ±0.5A, EIS (opt.); upgradable up to ±120A,

Description

SP-300 Potentiostat

2 channels – a fast, sensitive, stable and modular electrochemical workstation

A state-of-the-art research grade potentiostat with a 500 mA to 10 A range, built-in EIS and many other high-end specifications

Two channels – Fast, sensitive, stable and modular

The SP-300 is a state-of-the-art research grade potentiostat featuring a range of 500 mA to 10 A, built-in EIS and high-end specifications such as 7 MHz max frequency, floating mode, analog filtering, built-in calibration board, and stability bandwidths.

The SP-300 potentiostat’s modular chassis can integrate an optional high current/high voltage option board (up to 10 A & and up to 48 V), or alternatively, a second potentiostat board (either standard or EIS) to be used as a Bipotentiostat to carry out RRDE experiments. The instrument can also be used as a multiple user system as two different researchers can use each channel board independently.

General

General
Slots available Up to 2
Electrodes connections 2, 3, 4, 5
Compliance ± 12 V
Acquisition time 1 µs with ARG option, 20 µs with EC-Lab developer package, 200 µs with EC-Lab.
Live processed data : 200 µs, independent of sampling rate (Q charge, Q discharge, Energy, Power…)
Software EC-Lab, EC-Lab developper package
Add-ons compatibility Yes
Dimension (W x D x H) 205 x 410 x 225 mm
Weight 7.5 kg
Power requirement 350 W
Interfaces Ethernet (Direct, LAN, Wifi), USB 2.0

Channel specifications

Control
Measurement
Voltage
Ranges Customizable ranges. Adjustable from ± 10 V down to ± 30 mV.
Up to [0; 48] V with HCV-3048
± 10 V customizable
Accuracy < ± 1 mV ± 0.03 % of setting < ± 1 mV ± 0.03 % of reading
Resolution From 1 µV (± 60 mV range) to 333 µV (± 10 V range) 76 µV (7.6 µV for ± 250 mV, 0.76 µV for ± 25 mV, ZRA only)
Current
Ranges
± 1 A to 10 nA (9 ranges),
up to 120 A with four HCV-3048
down to ± 1 pA using Ultra Low Current option
Maximum current
± 500 mA
Accuracy < ± 0.1 % of range ± 0.03 % of setting < ± 0.1 % of range ± 0.03 % of reading
Resolution
0.004 % of the range : 760 fA (standard), 76 aA (Ultra Low Current option
EIS
EIS capability
11 MHz to 10 µHz
Frequency resolution
< 10 ppm of the setting
EIS quality indicators
Yes

Advanced

Advanced
Floating options FloatingWE to groundCE to ground
Permeation (WE to ground) Yes
Multi-electrode (CE to ground) Yes
Filters Hardware / Software
Input/Output 2x analog inputs
1x analog output
3x TTL (trigger input/output, and safety)
2x monitor outputs (current and voltage)
Stability control mode 9 bandwidths
Calibration One calibration board included, more than 100 verified points.